| UPX - 1P | UPX - 3P | ||
|---|---|---|---|
| Power firewood: | [kW] | 10 - 18 | 20 - 27 |
| The utilization of wood: | [%] | 92 | 91,3 |
| Power pellets: | [kW] | 5 - 18 | 9 - 29 |
| The utilization of pellets: | [%] | 93 | 93,2 |
| width: | [mm] | 1160 | 1220 |
| depth: | [mm] | 1289 | 1289 |
| Height: | [mm] | 1460 | 1600 |
| 1. Fuel storage room 2. Large loading doors 3. Inspection doors 4. Cleaning doors 5. The combustion nozzle 6. Turbulence combustion chamber 7. Pellet burning chamber 8. Heat Exchanger 9. An automatic mechanism for cleaning the exchanger 10. Smoke chamber with fan and lambda probe 11. Flue gas 12. Motor and primary air flap 13. Motor and secondary air flap 14. The display microprocessor control 15. The external boiler door 16. The cover of the boiler 17. Cover the fan |
![]() | Innovative patented vortex combustion chamber enables complete combustion of all the products and achieves record low emissions. |
|---|---|
![]() | The ease of maintenance due to the above-accessible electrical and electronic equipment. |
![]() | The latest technology for regulating the primary and secondary air and control the suction fan. |